Working volume : 150L
Temperature range : -40 ℃~ +150 ℃
Humidity range : 20 %RH~ 98 %RH
IEC 60335 Programmable Temperature Humidity Chamber PTH-1000 (150L) ,-40 ℃~ +150 ℃,
20 %RH~ 98 %RH
Standard
IEC60335-2-17, Clause 21.110.3, Clause 21.111.2.
Application
It is used to process the aging test for the blanket’s flexible fabric parts.
Test sample
Blanket’s flexible fabric parts.
Feature
Box type
Parameters
| Product Name | Programmable Temperature Humidity Chamber |
| Volume, size and weight | |
| Working Volume | 150L (can be customized) |
| Inner size | W500mm × H600mm × D500mm |
| Outer size | W1020mm × H1000mm × D1460mm |
| Weight | 300KG |
| Performance | |
| Test environmental conditions | Environmental temperature +5~+28℃, relative humidity≤85%, under the condition that no sample inside the test chamber |
| Test method | According to IEC60068-2, IEC60598-1 |
| Temperature range | -40℃~+150℃ |
| Temperature control precision | ±0.2℃ |
| Humidity control precision | ±2.5% RH |
| Temperature uniformity | ±2℃ |
| Humidity uniformity | ±3.0% RH |
| Heating up time | 3℃/min (Average heating up rate) |
| Cooling down time | 1℃/min (Average cooling down rate) |
*Note: Please refer to below humidity use range chart!

4. Temperature and humidity control accuracy: ±0.2℃; ±2.5%RH.
* To guarantee above 2~4 performance, should be measured 30 minutes after the temperature sensing measurements is stable!
5. Temperature and humidity distribution uniformity: ±2℃; ±3%RH.
*Note: To guarantee below 6~11 performance, the measuring positions should be each wall’s 1/6 positions of the test zone, and should be measured 30 minutes after the temperature is stable!
6. Heating time: Heating from the room temperature to 150℃, the total heating time is 50 mins (under non-load state).
7. Cooling time: Cooling from the room temperature to -40℃, the total cooling time is 40mins (under non-load state).
8. Inner chamber dimensions: test area: 50×60×50cm(W×H×D).
*Note: The volume of placing samples should not exceed 2/3 of the capacity of the test zone.
9. Equipment installation space: at least 920×1600×870cm(W×H×D).
10. Test chamber door: 80 × 105 cm(W×H), total 1.
11. Power source: AC 1 ∮ 220 V 50 Hz MAX 40 A
Picture for reference

|
|
IEC60335-2-17 Programmable Temperature Humidity Chamber PTH-1000 (150L) ,-40 ℃~ +150 ℃,20 %RH~ 98 %RH Images |